I. Standards
A. EPA Booklet on Mold Remediation in School
& Commercial Buildings
B. IICRC S500 Standards
C. OSHA 29 CFR 1910.134.63. Fr DTD 01/08/98
and all safety
applicable standards set
D. All Professional standards as directed by
new information on a daily basis
II. Building Walkthrough Checklist
III. Scope of Work
A. Thorough Briefing with Building
Managers/Owner's Representative
1. Discuss process for the building and
discuss every issue on
Building
Walkthrough Checklist
B. Contain area to be remediated
1. Set-up desired containment as per
protocol for each project
2. Set-up De-Con as required (Air Lock)
3. Install
HEPA filtered exhaust unit
exhausted to exterior of building
4. Ensure a minimum of four air changes
per hour and maintain
negative air
pressure differential of 0.02 inches of water
inside
the work area
IV. PPE Minimum for Entrance to Contained
Area
A. Gloves
B. N-95 Disposable Respirator
C. Goggles/Eye Protection
D. Disposable Coveralls
V. Perform Remediation I/A/W Protocol
Developed by IH or Building Owner
VI. Post Clearance
A. Upon Completion, final cleaning test, if
required, will be performed
and maintained until final results
VII. MSDS Sheets
A. Fosters 40/20, 40/80
B. Oxine
C. Bleach
D. Simple Green
E. Any other chemicals requested by the Owner
VIII.
Work Hours
A. Flexible (Day, Night, Weekends, as
requested) |